EasyManua.ls Logo

DRAGFLOW EL7.5 - Maintenance Operating Instructions; Lubricating Oil Checking

DRAGFLOW EL7.5
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DRAGFLOW S.r.l. - Sede legale: Via Satiro, 11 37121 VERONA Italy
Sede amm.: Via Paesa 46048 ROVERBELLA (MN) Italy Tel. +39 0376 1685400
Fax +39 0376 1685499 - Cod. Fisc e P. IVA : IT 02757460239 R.E.A. Verona n. 280092
Registro Impr. Di Verona n. 189595/1997 Capitale Sociale 10.400 interamente versato
EL7.5 - EL12.5 (S - SS) User manual - ENG 38/70
5.3 Maintenance operating instructions
5.3.1 Lubricating oil checking
The lubricating oil check must be performed every 8 hours. The purposes of this
operation are:
- to verify the oil quantity;
- to verify the oil condition.
Check the quantity/condition of the lubricating oil in the oil chamber by slightly
unscrewing the “OIL” plug [A] (without removing it) (see Fig. 19):
Fig. 19
With the pump in vertical position, some drop of oil must exit from the partilally
plugged hole if the quantity is correct. Refill eventually (see Lubricating oil
changing/refilling).
Check a sample of oil to understand its condition and presence of impurity or water.
In case of deterioration of the oil provide for its complete replacing (see Lubricating
oil changing/refilling). In case of presence of impurity or water, provide also for a
seals replacing (call the Service Department or see Lower seals and Upper seals in the
Service Manual).

Table of Contents