5.3 Maintenance operating instructions
5.3.1 Lubricating oil checking
The lubricating oil check must be performed every 8 hours. The purposes of this
operation are:
- to verify the oil quantity;
- to verify the oil condition.
Check the quantity/condition of the lubricating oil in the oil chamber by slightly
unscrewing the “OIL” plug [A] (without removing it) (see Fig. 19):
Fig. 19
With the pump in vertical position, some drop of oil must exit from the partilally
plugged hole if the quantity is correct. Refill eventually (see Lubricating oil
changing/refilling).
Check a sample of oil to understand its condition and presence of impurity or water.
In case of deterioration of the oil provide for its complete replacing (see Lubricating
oil changing/refilling). In case of presence of impurity or water, provide also for a
seals replacing (call the Service Department or see Lower seals and Upper seals in the