Section 5: Programming
l Receiver 4 backs up Receiver 3
This continues until communication is successful or the sequence has been repeated 5 times (depending on the number of
maximum dialing attempts). If all 5 attempts fail, an FTC trouble for the primary phone number is logged. All backup receivers
automatically use the same call directions and format as the primary receiver.
OFF: After 5 failed attempts to communicate with the primary receiver, the communicator switches to the next backup
receiver in the sequence and makes up to 5 more attempts. This continues until communication is successful or until all
backup receivers fail, at which point an FTC trouble for the primary number is logged.
7 Reduced Dialing Attempts
ON: If a TLM trouble is present, The alarm system immediately attempts to call the backup receiver. This option only applies
to PSTN. Backup communications must be enabled. See option 5, Parallel Communications.
A minimum of two receivers should be enabled for this feature to operate as intended. This feature should not be enabled
unless the panel is programmed to use backup communication paths.
OFF: If a TLM trouble is present, the number of dialing attempts programmed shall be attempted before moving on to the
backup receiver.
8 Activity Delinquency
ON: Inactivity on a partition for a programmed duration (section [377] option 002, Delinquency Transmission Delay) transmits
a Delinquency code to the central station. This option is designed to help monitor the elderly or disabled. The counter is
reset if zone activity is detected or if the system is armed. The Delinquency Transmission Delay is in hours.
Note: Delinquency code is not transmitted while Away armed. Activity on bypassed zones does not affect this timer.
OFF: The Delinquency reporting code is sent when the programmed number of days for delinquency (section [377]) expires
without the partition being Armed. Once the code is sent, the timer is not started again until the partition has been armed.
Each day programmed in the counter represents one day plus the time it takes for the partition to reach midnight. To disable
this feature, program 000 in section [377]>[002] option 5.
[381] Communicator Option 2
1 Keypad Ringback
ON: When the Opening After Alarm reporting code is successfully transmitted to a programmed telephone number, the
keypad emits a series of 8 beeps to confirm to the occupant that the code was sent and received. Ringback occurs for each
successfully reported Opening After Alarm code.
OFF: When the Opening After Alarm reporting code is successfully transmitted to a programmed telephone number, the
keypad does not sound ringback.
2 Bell Ringback
ON: When the Opening After Alarm reporting code is successfully transmitted to a programmed telephone number, the siren
emits a series of 8 squawks to confirm to the occupant that the code was sent and received. Ringback occurs for each suc-
cessfully reported Opening After Alarm code.
OFF: When the Opening After Alarm reporting code is successfully transmitted to a programmed telephone number, the siren
does not sound ringback.
4 Closing Confirmation Enabled/Disabled
ON: When a Closing reporting code is successfully transmitted to a programmed telephone number, the keypad emits a
series of 8 beeps to confirm to the occupant that the Closing Code was sent and received.
OFF: No keypad ringback is generated when a Closing reporting code is successfully transmitted.
8 Communications Priority Enabled/Disabled
ON: Events follow the priority level indicated in ULC-S559 standard.
Concurrent event communications are prioritized in the following order (highest to lowest priority):
1. Fire Alarms
2. CO Alarm
3. Fire Supervisories
4. Fire Trouble
5. Monitoring (Medical, Panic or Security)
6. All others such as restorals for fire alarms, supervisories, troubles and monitoring.
- 110 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo and is the answer not in the manual?

DSC Neo Specifications

General IconGeneral
ModelDSC Neo
CategorySecurity System
PartitionsUp to 8
TypeHybrid Security System
ZonesUp to 128 zones
CommunicationCellular, IP
CompatibilityPowerG wireless sensors
Remote AccessYes, via app
PGMs4
Wireless RangeUp to 2 km with PowerG
Event Buffer1000 events
Wireless Frequency433 MHz, 868 MHz
Power Supply16.5VAC, 40VA
Battery BackupYes, 12VDC 7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)
Event LogYes