Appendix 1: Reporting Codes
Section # Definition Dialer Dir-
ection*
Automatic Contact ID
Codes
SIA Auto Rep Codes**
[308]-[011] Alarm Canceled before expiry of alarm cancellation timer A/R E(4)A6-UUU OC-UUUU
[308]-[011] PGM2 (Silent 24 Hour Input) -Aux Input Alarm/restore A/R E(1)46-992
R(1)46-992
UA-0992 / UH-0992
[308]-[011] PGM2 (Audible 24 Hour Input) -Aux Input Alarm/restore A/R E(1)4A-992
R(1)4A-992
UA-0992 / UH-0992
[308]-[305] PGM2 2-Wire Smoke Alarm/Restore A/R
E(1)11-992
R(1)11-992
FA-0992 / FH-0992
Priority Alarm and Restoral Events
[F] Key alarm/restore A/R E(1)1A-000
R(1)1A-000
FA-0000 / FH-0000
[M] Key alarm/restore A/R E(1)AA-000
R(1)AA-000
MA-0000 / MH-0000
[P] Key alarm/restore A/R E(1)2A-000
R(1)2A-000
PA-0000 / PH-0000
Miscellaneous Closing
[308]-[221] Zone Bypass at time of arming O/C E(5)7A-ZZZ UB-ZZZZ
[308]-[221] Zone Unbypass
O/C R(5)7A-ZZZ UU-ZZZZ
Testing
[308]-[401] Walk Test Begin/End T E(6)A7-UUU
R(6)A7-UUU
TS-UUUU/TE-UUUU
[308]-[401] Periodic Test T E(6)A2-000 RP-0000 / RY-0000
[308]-[401] Periodic Test with Trouble T E(6)A8-000 RY-0000
[308]-[401] System Test - [*][6] bell/communications test T E(6)A1-000 RX-0000
Maintenance
[308]-[311] General System trouble/restore - An RF jam trouble
occurred/was restored
MA/R E(3) AA-000
R(3) AA-000
YX-0000 / YZ-0000
[308]-[311] Fire trouble/restore MA/R E(3)73-000
R(3)73-000
FT-0000 / FJ-0000
[308]-[314] Gas trouble/restore MA/R E(3)8A-ZZZ
R(3)8A-ZZZ
GT-ZZZZ / GJ-ZZZZ
[308]-[314] Heat trouble/restore MA/R E(3)8A-ZZZ
R(3)8A-ZZZ
KT-ZZZZ / KJ-ZZZZ
[308]-[314] Freeze Trouble / Restore MA/R
E(3)8A - ZZZ
R(3)8A - ZZZ
ZT-ZZZZ / ZJ-ZZZZ
Carbon Monoxide Trouble MA/R
E(3)8A - ZZZ
R(3)8A - ZZZ
UT-ZZZZ / UJ-ZZZZ
[308]-[311] Cold Start - System has restarted after total power loss MA/R R(3) A5-000 RR-0000
[308]-[312] Event Buffer 75% Full MA/R E(6)22-000 JL-0000
[308]-[312] DLS Lead In - Download session start MA/R E(4)11-000 RB-0000
[308]-[312] DLS Lead Out - Download session stop MA/R E(4)12-000 RS-0000
[308]-[312] SA Lead In - Download session start MA/R E(4)11-000 RB-0000
[308]-[312] SA Lead Out - Download session stop MA/R E(4)12-000 RS-0000
[308]-[312] Installer Lead In - Installer Programming has been entered MA/R E(6)27-000 LB-0000
[308]-[312] Installer Lead out - Installer Programming has been exited MA/R E(6)28-000 LS-0000
[308]-[313] Panel firmware update begin/ successful MA/R E(9)01-900
R(9)01-900
LB-0900 / LS-0900
- 198 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo and is the answer not in the manual?

DSC Neo Specifications

General IconGeneral
ModelDSC Neo
CategorySecurity System
PartitionsUp to 8
TypeHybrid Security System
ZonesUp to 128 zones
CommunicationCellular, IP
CompatibilityPowerG wireless sensors
Remote AccessYes, via app
PGMs4
Wireless RangeUp to 2 km with PowerG
Event Buffer1000 events
Wireless Frequency433 MHz, 868 MHz
Power Supply16.5VAC, 40VA
Battery BackupYes, 12VDC 7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)