Section 6: Programming Worksheets
o Receiver #2 o Receiver #4
[318] Partition 8 Call Directions
001 Partition 8 Alarm/ Restore: R Receiver #1 o Receiver #3
o Receiver #2 o Receiver #4
002 Partition 8 Tamper/ Restore: R Receiver #1 o Receiver #3
o Receiver #2 o Receiver #4
003 Partition 8 Opening/ Closing: o Receiver #1 o Receiver #3
o Receiver #2 o Receiver #4
[350] Communicator Formats
Description on page 107
(2-Digit decimal) 001 Receiver 1: 003 Receiver 3:
Range: 03= Contact ID, 04= SIA (Default) 002 Receiver 2: 004 Receiver 4:
[377] Communication Variables
(3-digit decimal)
Range: 000-255 attempts unless otherwise noted
Description on page 107
001 Swinger Shutdown Attempts: Alarms and Restore (000-014):
Default: 003 Tampers and Restore:
(
CP-01
Default: 002) Maintenance and Restore:
002 Communication Delays: Communication Zone Delay (Default: 000
CP-01
Default: 030):
AC Failure Communication Delay (Default:030
minutes/Hours):
TLM Trouble Delay (
NA
Default:010 checks
EN
Default:002 checks):
Wireless Zone Low Bat. Transmission Delay (Default: 007
days):
Delinquency Transmission Cycle Delay (Default: 030
days/hours):
Communications Cancel Window (Default: 000 minutes
CP-01
Default: 005 minutes):
003 Periodic Test Transmission Cycle (Default: 030 hours/days):
004 Periodic Test Transmission Time of Day (Default: 9999):
011 Maximum Dialing Attempts: (Default: 005):
012 Delay Between PSTN Attempts: (Default: 003 seconds):
013 Delay Between Force Attempts: (Default: 020 seconds):
014 Post Dial Wait for Handshake: (Range: 001-255; Default: 040 Seconds; UL=45):
015 IP/GS Wait for Ack: (Range: 001-255; Default: 060 seconds):
016 IP/Cellular Fault Check Timer: (Range: 003-255; Default: 010):
[380] Communicator Option 1
- 164 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo and is the answer not in the manual?

DSC Neo Specifications

General IconGeneral
ModelDSC Neo
CategorySecurity System
PartitionsUp to 8
TypeHybrid Security System
ZonesUp to 128 zones
CommunicationCellular, IP
CompatibilityPowerG wireless sensors
Remote AccessYes, via app
PGMs4
Wireless RangeUp to 2 km with PowerG
Event Buffer1000 events
Wireless Frequency433 MHz, 868 MHz
Power Supply16.5VAC, 40VA
Battery BackupYes, 12VDC 7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)
Event LogYes