Section 5: Programming
OFF: Squawks do not activate the main siren.
[001]-[164] PGM 001-164 Attributes
The following PGM attributes can be assigned to a PGM. Each attribute has various toggle options, depending on the PGM
type selected (section [009]).
101 Fire and Burglary
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
102 Delay Fire and Burglary
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
103 Sensor Reset [*][7][2]
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
03 Access Code Required / No Code Required
ON: Access code required for activation
OFF: No access code required for activation
109 Courtesy Pulse
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
111 Keypad Buzzer Follow
01 True Output/Inverted
ON: deactivated during normal operation, activated when triggered.
OFF: activated during normal operation, deactivated when triggered.
02 Timed Output
ON: output remains active until the PGM output timer expires.
OFF: output remains active until the buzzer condition ends.
09 Entry Delay
ON: activates on entry delay.
OFF: does not activate on entry.
10 Exit Delay
ON: activates on exit delay.
OFF: does not activate on exit delay.
11 Door Chime
ON: activates when chime is enabled.
OFF: does not activate when chime is enabled.
12 Keypad Buzzer Zone
ON: activates when keypad buzzer goes into alarm.
OFF: does not activate when keypad buzzer goes into alarm.
13 Audible Exit Fault
ON: activates when audible exit fault pre-alert begins.
OFF: does not activate when audible exit fault pre-alert begins.
- 78 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo and is the answer not in the manual?

DSC Neo Specifications

General IconGeneral
ModelDSC Neo
CategorySecurity System
PartitionsUp to 8
TypeHybrid Security System
ZonesUp to 128 zones
CommunicationCellular, IP
CompatibilityPowerG wireless sensors
Remote AccessYes, via app
PGMs4
Wireless RangeUp to 2 km with PowerG
Event Buffer1000 events
Wireless Frequency433 MHz, 868 MHz
Power Supply16.5VAC, 40VA
Battery BackupYes, 12VDC 7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)
Event LogYes

Related product manuals