Appendix 3: Template Programming Tables
6 Receiver 1 and 2 CIA with backup [380] Comm Toggles 1 - Bit 1 Communications Enabled - On
[350] Communicator Formats - [001] Receiver 1 - 03 CID
[350] Communicator Formats - [002] Receiver 2 - 03 CID
[350] Communicator Formats - [003] Receiver 3 - 03 CID
[350] Communicator Formats - [004] Receiver 4 - 03 CID
[384] Comm Backup - Bit 2 Receiver 2 Backup - On
[384] Comm Backup - Bit 2 Receiver 2 Backup - Off
[384] Comm Backup - Bit 2 Receiver 2 Backup - Off
[300] Comm Path - [001] Receiver 1 - 01 PSTN
[300] Comm Path - [002] Receiver 2 - 01 PSTN
[300] Comm Path - [003] Receiver 3 - 01 PSTN
[300] Comm Path - [004] Receiver 4 - 01 PSTN
Digit 4 Reporting Code Configuration Options
Option Common Group Selected Troubles Openings/ Closings Zone Alarm Restore DLS/Installer Lead In/Out
1 Y Y Y
2 Y Y Y Y
3 Y Y Y Y
4 Y Y Y Y Y
5 Y Y Y
6 Y Y Y
7 Y Y Y Y
8 Y
4 indicates included, blank indicates default setting, 6 indicates disabled
Common Group
Common Group Common Group Programming
Set all reporting codes to automatic [308] Event Reporting - All Events On
Alarm/restore call directions enabled [311][001] Partition 1 Alarm/Restore - Bit 1 Receiver 1 - On
[311][001] Partition 1 Alarm/Restore - Bit 2 Receiver 2 - Off
[311][001] Partition 1 Alarm/Restore - Bit 3 Receiver 3 - Off
[311][001] Partition 1 Alarm/Restore - Bit 4 Receiver 4 - Off
Tamper/restore call directions disabled [311][002] Partition 1 Tamper/Restore - Bit 1 Receiver 1 - Off
[311][002] Partition 1 Tamper/Restore - Bit 2 Receiver 2 - Off
[311][002] Partition 1 Tamper/Restore - Bit 3 Receiver 3 - Off
[311][002] Partition 1 Tamper/Restore - Bit 4 Receiver 4 - Off
Opening/closing call directions disabled [311][003] Partition 1 Open/Close - Bit 1 Receiver 1 - Off
[311][003] Partition 1 Open/Close - Bit 2 Receiver 2 - Off
[311][003] Partition 1 Open/Close - Bit 3 Receiver 3 - Off
[311][003] Partition 1 Open/Close - Bit 4 Receiver 4 - Off
- 204 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo and is the answer not in the manual?

DSC Neo Specifications

General IconGeneral
ModelDSC Neo
CategorySecurity System
PartitionsUp to 8
TypeHybrid Security System
ZonesUp to 128 zones
CommunicationCellular, IP
CompatibilityPowerG wireless sensors
Remote AccessYes, via app
PGMs4
Wireless RangeUp to 2 km with PowerG
Event Buffer1000 events
Wireless Frequency433 MHz, 868 MHz
Power Supply16.5VAC, 40VA
Battery BackupYes, 12VDC 7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)
Event LogYes