EasyManuals Logo

DSC Neo User Manual

DSC Neo
236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
Section 4: System Operation
[39] Trouble Display
This function puts the keypad in trouble display mode and is equivalent to pressing [*][2]. This function only works while the
system is disarmed. This function key requires a code if section [023] option 5 is enabled.
[40] Alarm Memory
This function puts the keypad in alarm memory display mode and is equivalent to pressing [*][3]. This function only works
while the system is disarmed. This function key requires a code if section [023] option 6 is enabled.
[61]-[68] Partition 1 to 8 Select
This function selects partition 1-8 when the assigned key is pressed. Pressing and holding the key for 2 seconds selects the
next partition.
4.6 Language Selection
The keypad can be programmed to display messages and labels in different languages. Perform the following from the
Installer Programming menu:
1. Enter installer programming [*][8][installer code]
2. Enter section [000]>[000].
3. Select a language using the scroll buttons or by entering a hotkey:
Table 4-3 Languages
[01] English [15] Greek
[02] Spanish [16] Turkish
[03] Portuguese [18] Croatian
[04] French [19] Hungarian
[05] Italian [20] Romanian
[06] Dutch [21] Russian
[07] Polish [22] Bulgarian
[08] Czech [23] Latvian
[09] Finish [24] Lithuanian
[10] German [25] Ukrainian
[11] Swedish [26] Slovakian
[12] Norwegian [27] Serbian
[13] Danish [28] Estonian
[14] Hebrew [29] Slovenian
4. Press [#] to exit.
4.7 [*] Commands
[*] commands provide convenient access to alarm system features. The following commands are available:
[*][1] Bypass zones
[*][2] View troubles
[*][3] View alarms in memory
[*][4] Door chime on/off
[*][5] User programming
[*][6] User functions
[*][7] Command output 1-4 on/off
[*][8] Installer programming mode
- 42 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo and is the answer not in the manual?

DSC Neo Specifications

General IconGeneral
ModelDSC Neo
CategorySecurity System
PartitionsUp to 8
TypeHybrid Security System
ZonesUp to 128 zones
CommunicationCellular, IP
CompatibilityPowerG wireless sensors
Remote AccessYes, via app
PGMs4
Wireless RangeUp to 2 km with PowerG
Event Buffer1000 events
Wireless Frequency433 MHz, 868 MHz
Power Supply16.5VAC, 40VA
Battery BackupYes, 12VDC 7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)
Event LogYes