EasyManuals Logo

DSC Neo User Manual

DSC Neo
236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #79 background imageLoading...
Page #79 background image
Section 5: Programming
14 Auto-Arm Pre-Alert
ON: activates when auto-arming pre-alert begins.
OFF: does not activate when auto-arming pre-alert begins.
114 Ready To Arm
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
115 Armed Status
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
116 Armed Away Mode
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
117 Armed Stay Mode
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
120 Away Armed with No Zone Bypasses Status
01 True Output/Inverted
ON: deactivated during normal operation, activated when triggered.
OFF: activated during normal operation, deactivated when triggered.
121-124 Command Output 1-4
01 True Output/Inverted
ON: deactivated during normal operation, activated when triggered.
OFF: activated during normal operation, deactivated when triggered.
02 Timed Output / Latched Output
ON: output remains active until the PGM output timer expires.
OFF: output remains active until an access code has been entered.
03 - Access Code Required / No Code Required
ON: access code required for activation.
OFF: no access code required for activation.
129 Partition Status Alarm Memory
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
132 Holdup Output
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
146 TLM Alarm
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
- 79 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo and is the answer not in the manual?

DSC Neo Specifications

General IconGeneral
ModelDSC Neo
CategorySecurity System
PartitionsUp to 8
TypeHybrid Security System
ZonesUp to 128 zones
CommunicationCellular, IP
CompatibilityPowerG wireless sensors
Remote AccessYes, via app
PGMs4
Wireless RangeUp to 2 km with PowerG
Event Buffer1000 events
Wireless Frequency433 MHz, 868 MHz
Power Supply16.5VAC, 40VA
Battery BackupYes, 12VDC 7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)
Event LogYes