Section 5: Programming
7. FTC'ed events
OFF: Events are communicated in the order they occur.
ULC
Note: Must be ON for ULC commercial fire monitoring listed installations.
[382] Communicator Option 3
1 Not Used
2 Walk Test Communications
ON: Zone alarms that occur during Walk Test are communicated if programmed to do so.
OFF: Zone alarms during Walk Test are not communicated. FMP key alarms are still communicated.
4 Call Waiting Cancel
ON: The call waiting cancel string (See "[304] Call Waiting Cancel String" on page 100) is used on the first attempt to dial
each phone number. It is not used on any further dialing attempts.
OFF: The call waiting cancel string is not dialed.
5 Alternate Communicator Enable/Disable
ON: The system communicates using the alternate communicator. All related programming options, reporting and super-
vision are enabled when programmed via PC-Link2.
OFF: The alternate communicator and all associated programming functionality are disabled. The auto time update feature is
disabled.
Note: If alternate communicator troubles are present when the communicator is disabled, the troubles are logged, com-
municated, and cleared from [*][2]. When the communicator is re-enabled, the trouble conditions are again logged, com-
municated and indicated in [*][2]. This option must be enabled when attempting to perform a firmware upgrade using the PC-
link header.
6 AC Failure Communication Delay in Hours/Minutes
ON: The AC failure communication delay (section [377]>[002] option 2) is programmed in hours.
OFF: The AC failure communication delay is programmed in minutes.
8 Tamper Limit
ON: When disarmed, the system only communicates module tampers. Zone tampers are not communicated.
OFF: When disarmed, the system communicates all tampers.
[383] Communicator Option 4
1 Phone Number Account Code
ON: The account code communicated to the central station follows the phone number the event is programmed to com-
municate on (programmed in section "[310] Account Codes" on page 106):
l Receiver 1 all events will follow partition 1 account code
l Receiver 2 all events will follow partition 2 account code
l Receiver 3 all events will follow partition 3 account code
l Receiver 4 all events will follow partition 4 account code
OFF: Events follow the account code assigned to each partition when communicating.
Note: This feature only works with CID
2 4 or 6-Digit System Account Code
ON: The programmable account code in section [310][000] is 6 digits long (used for SIA format).
OFF: The programmable account code in section [310][000] is 4 digits long.
5 Communicate FTC Events
ON: The alarm system communicates FTC (failure to communicate) events. The FTC Trouble/Restore reporting code trans-
mission follows the call direction the events are assigned to.
OFF: FTC events are not communicated. FTC Trouble/Restore reporting codes are communicated to the Maintenance call
direction group after the next successful communication.
- 111 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo and is the answer not in the manual?

DSC Neo Specifications

General IconGeneral
ModelDSC Neo
CategorySecurity System
PartitionsUp to 8
TypeHybrid Security System
ZonesUp to 128 zones
CommunicationCellular, IP
CompatibilityPowerG wireless sensors
Remote AccessYes, via app
PGMs4
Wireless RangeUp to 2 km with PowerG
Event Buffer1000 events
Wireless Frequency433 MHz, 868 MHz
Power Supply16.5VAC, 40VA
Battery BackupYes, 12VDC 7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)
Event LogYes