4-9
Chapter 4 Using Options
1-7. Manual feed timing setting
The period of time from inserting paper into the inlet to starting folding operation can be changed.
Default : [Normal]
OtherSetting 1/4
Stack Roll Adj
Oper Mode
Test Feed Set
1
Press the menu key to display [Other Setting].
OtherSetting 4/4
mm/inch Setting
M-Feed Timing
2
Select [M-Feed Timing] with the or
key.
M-Feed Timing
Normal
3
Press the key.
[M- Feed Timing] screen is displayed, and
[Slow], [Normal], or [Fast] can be changed.
4
Select the speed with the key or
key.
M-Feed Timing
Slow
5
Press the key.
The selected details are set.
6
Press the key.
Returns to the [Other Setting].
7
Press the key.
Returns to the top screen.