Maintenance
Operating Instructions 669 - 00.0 - 08/2019 59
2. Turn the pressure controller until the pressure gage (2)
indicates the proper setting:
Increase pressure = turn clockwise
Reduce pressure = turn counterclockwise
3. Push the pressure controller (1) down.
5.3.2 Draining the water condensation
Water condensation accumulates in the water separator (2) of the
pressure controller.
Proper setting
Water condensation must not rise up to the level of the filter
element (1).
Check the water level in the water separator (2) on a daily basis.
Fig. 29: Draining the water condensation
NOTICE
Property damage from excess water!
Excess water can cause damage to the machine.
Drain water as required.
(1) - Filter element
(2) - Water separator
(3) - Drain screw