Setup
Operating Instructions 669 - 00.0 - 08/2019 89
3. Fasten the Hall sensor (6) to the holder (5) using screws (4).
4. Fasten the holder (5) with the Hall sensor (6) to the arm using
screws (8).
Guide the cable (3) through the clip (7).
5. Route cable (3) in the arm and then to the control cabinet
under the tabletop.
6. Screw on the arm cover (1).
7. Connect the 9-pole Sub-D plug from the Hall sensor (6) into
B18 socket on the EFKA DA321G control.
Fig. 58: Connecting the Hall sensor (3)
8. Remove plate (9) from belt guard (10).
Cut through the holders (11) with a sharp knife.
9. Mount the protective belt cover (10) on the machine head.
10. Mount the handwheel.
(9) - Plate
(10)- Protective belt cover
(11)- Holder