49
15
AC Input Load
Timer Settings
This setting allows the user to
set the Start/End times for the
Grid/Utility to supply power to
the load.
Start Time1-3: 00:00 23:59
Default: 00:00 00:00
End Time1-3: 00:00 23:59
Default: 00:00 00:00
17
Battery Wakeup
This setting allows the user to enable or
disable the battery wakeup feature. It is
not applicable if no battery type is
defined.
Range: Enable/Disable
18
Max Generator
Input Power
This setting allows the user to
set the maximum generator
input power.
Range: 0-7369W
Default: 7369
19
PV Off-Grid
Enable/Disable
This setting allows the user to
configure the system to only
use PV for loads. Due to
voltage fluctuation, power
output may be inconsistent.
Range: Enable/Disable
Default: Enable

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EG4 LuxPowerTek 6000XP and is the answer not in the manual?

EG4 LuxPowerTek 6000XP Specifications

General IconGeneral
CategoryInverter
Rated Power6000W
Max DC Input Power7800W
Number of MPPT Trackers2
Battery Voltage48V
Max Charge/Discharge Current120A
Protection DegreeIP65
Frequency50/60Hz
ModelLuxPowerTek 6000XP
CommunicationRS485
Operating Temperature Range-25°C to 60°C
Protection FeaturesOver Voltage Protection, Over Temperature Protection