50
20
Power Save
Function
This setting allows the user to
enable or disable the Power
Save Functions, Green
Functionand ECO Mode.
Range: Enable/Disable
The default settings for both
functions are set to disabled.
21
Parallel Setting
This setting allows the user to
select the inverter paralleling
configuration.
Parallel Type: NoPL (Not Parallel), 1PH (Single Phase), 3PH (Three Phase)
Default: NoPL
Parallel Phase: P1 (R-Phase), P2 (S-Phase), P3 (T-Phase)
Default: P1 (R-Phase)
Battery Share Enable/Disable: Disable/Enable
Default: Disable
22
Error/Alarm
Record
This setting allows the user to
see Error and Alarm records.
Error Record:->Record Setting->Record Message
(Year:Month:Day; Hour:Min:Sec; Error Code)
Alarm Record:->Record Setting->Record Message
(Year:Month:Day; Hour:Min:Sec; Alarm Code)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EG4 LuxPowerTek 6000XP and is the answer not in the manual?

EG4 LuxPowerTek 6000XP Specifications

General IconGeneral
CategoryInverter
Rated Power6000W
Max DC Input Power7800W
Number of MPPT Trackers2
Battery Voltage48V
Max Charge/Discharge Current120A
Protection DegreeIP65
Frequency50/60Hz
ModelLuxPowerTek 6000XP
CommunicationRS485
Operating Temperature Range-25°C to 60°C
Protection FeaturesOver Voltage Protection, Over Temperature Protection