63
Chapter 3 Conguring from a Web Browser
●
Communication Settings
The communication settings are used to congure the web interface function, detection of
communication errors, and so on.
1. In “System”, select “Communication Settings”.
The “Communication Settings” screen is displayed.
2. Congure the items.
Item Detail Setting range
Communication
Speed
Set the communication speed between the monitor and
network hub.
100Mbps Half duplex
/
100Mbps Full duplex
/
1000Mbps Full duplex
Communication Error
Detection
You can set the following as the message to be displayed
when receipt of image data stops.
Communication Error Detection On:
Within several seconds after receipt of image data stops,
an alert message in a red box will appear on the live image
screen. When communication resumes, the alert is cleared
and the image is displayed again.
Communication Error Detection Off:
When approx. 20 seconds have elapsed after receipt of
image data stops, a communication error message will
appear.
On / Off
Web Interface You can operate and congure the monitor from your web
browser over the network.
On / Off
*1
Web Interface Port Sets the port of the web interface
*2
1 to 65535
AUTH Method Sets the authentication method for the web interface.
*2
Digest authentication /
BASIC authentication
*1 The web interface cannot be set to Off if USB lock (page 64) and Remote lock (page 64) are set
to On.
*2 Can be specied when the web interface is set to On.
3. Select “Apply”.
The setting complete screen is displayed. Select “OK”.
Attention
• When the web interface is disabled, you will not be able to congure the monitor settings from your web
browser. When the web interface is disabled and “Apply” is selected, the following warning message
appears.