E L A N H O M E S Y S T E M S
INSTALLATION MANUAL
© ELAN Home Systems 2009 • All rights reserved. Page 75
S86A
Examples:
&S86,DND,13,0<cr> turns Zone 13’s DND off.
&S86,DND,02?<cr> queries Zone 2’s DND.
&S86,DND,13,1<cr> turns Zone 13’s DND on.
&S86,DND,13,2<cr> toggles Zone 13’s DND from on to off or off to on.
DB
Description:
Turns specified DB off/on/toggle. This will initiate a DB that will route audio present at
the S86’s Page In audio jack to zones that have DB enabled.
Works if the System/Zone is on or off.
Only chassis one will respond.
Command:
&S86,DB,a<cr>
Query:
&S86,DB?<cr>
Reply:
&S86,DB,a<cr>
Parameters:
<cr>:
carriage return: Hexadecimal 0x0D or Decimal 13
a:
0 = OFF
1 = ON
2 = Toggle
Examples:
&S86,DB,0<cr> turns Doorbell off.
&S86,DB?<cr> queries Doorbell status.
&S86,DB,2<cr> toggles Doorbell from on to off or off to on.