5
Product description
The TRIGON L PLUS is a condensing
andmodulatinggasboilerwithoneor
twopre-mixburners,oorstanding.Itis
characterizedbythefollowingfeatures:
- A large modulation range that
guaranteesalongburnerservice
life,whileminimizingstandby
losses, start-up emissions and
material wear-and-tear.
- Fluegastemperaturebelow80°C
- Alsosuitableforroomsealed
conditions
- Control panel with all operational
elements
- Microprocessor, with multi-
functional display
- Automated ignition, with repetition
and ionization monitoring
- Water pressure monitoring
- Energy-saving pump
- Stainless steel heat exchanger
withsmoothtubecondenser
- Very maintenance-friendly
- Ready for weather-compensated
control (accessory)
- Cascadecontrollerupto8boilers
- Externalcontrols(accessory)by
on/o,eBusor0-10V
- Modern metal panelling,
stove-enamelled
Functional description
Thecontrolunitmodiestheheating
performance to the current heating
requirements,bychangingthe
default values of the fan rotating
speed.Inthisregard,theboilerow
temperature is continually measured
via a sensor. In case of a deviation
of the actual temperature from the
target temperature, the control unit
reacts immediately and adjusts the
RPMofthefan,andwiththattheboiler
performance via the gas armature.
Adeviationcanbedueto:
- A changed default value of the
boilertemperature,viatheATG
heating control unit
- A change on the outdoor
temperature
- Request for Domestic Hot Water
- Changed heating curve
By means of the integration of the
individual components in a system,
and within the control range of the
equipment,itisensuredthattheboiler
performance always corresponds to the
actual heating requirements.
Delivery scope
Theboiler,whichhasbeenassembled
at the factory and is ready to use,
isdeliveredincardboardpackaging.
The following is contained in the
delivery scope of the TRIGON L PLUS:
- Modulatinghigheciency
gas-redboiler,16.5to200kW
- Higheciencypump(s)
- Boiler/Cascade controller
Accessories:
- Boilerconnectionttings
- Headersfor2and3boilers
- Low loss headers up to 1600kW
- Plate heat exchanger up to 800kW
- Insulation packs
- Boiler frames for free standing units
- Exhaustpipeconnectionttings
- Control for 3 extra heating zones
- Openbustranslator
For detailed information see the
chapter “delivery scope”.
Legend:
1. heatexchanger1(seetable)
2. heatexchanger2(seetable)
3. ignition electrode
4. detection electrode
5. fan unit
6. venturi
7. gas valve
8. automatic air vent
9. manual air vent
10. main switch 230V
11. boilercontrolunit
12. control unit HMI
13. connection terminal
14. connection terminal cascade
buscommunication
15. connection terminal pc
16. dirt collector
17. circulation pump
18. water no return valve
19. ueconnection
20. air supply
21. collectiveuepipe
22. information plate
23. drainage cap
24. clip 3 zone (optional)
25. air/ueconnectionconcentric
(optional for Thision L Plus
60-70-100-120-140)
26. water pipe connection
1 1/2" (optional)
27. gas pipe connection
1" (optional)
T1 owsensor
T1asecondaryowsensor
T2 return sensor
P1 water pressure sensor
APS Air Pressure Switch
HV high voltage electrical supply
LV low voltage electrical supply
G gas pipe
A owpipeCH
R return pipe CH
C condensate drain pipe
Product description
TRIGON L PLUS
Boiler type Exchanger 1 Exchanger 2
60 iCon XL1 -
70 iCon XL1 -
100 iCon XL2 -
120 iCon XL1 iCon XL1
140 iCon XL1 iCon XL1
170 iCon XL2 iCon XL1
200 iCon XL2 iCon XL2