40
40 EN
EPIR3 User Manual v1.3
3.3.7. How to bypass a violated zone & activate a bypassed zone by EKB3W
Arming the system is disabled while there’s at least 1 violated zone. Bypassing the zone allows to temporally dis-
able a particular violated zone and arm the alarm system afterwards.
Bypass a violated zone by entering the following combination using [BYPS], number and [#] keys:
1
7
4
2
8
5
0
3
9
6
Press the [BYPS] key, enter zone number & user code:
BYPS nn uuuu#
Value: nn – zone number, range – [01... 34]; uuuu – 4-digit
user code
Example: BYPS051111#
To activate a bypassed zone, enter the same combination again.
NOTE: The alternative way to activate all bypassed zones at once is to disarm the system.
NOTE: Zones can only be bypassed when the system is not armed.
The Conguration mode must be deactivated, while bypassing and activating a bypassed zone.