4 Advanced System Operation
iConnect Installation Manual
36
RSSI level is 5 and the TX signal strength is 6, consider relocation of the Control System or its peripherals – see p. 9 2.1.1
Wireless Installation Guidelines.
The menu will have timeout of 5 minutes. If the installer doesn't exit the menu within 5 minutes of its entry, the Control
System will exit all menus.
To view the RF RSSI level reading:
From the Service menu, select RF & GSM level, RF RSSI Level [7092]; the RF RSSI level of the Control
System's receiver is displayed.
4.8.11. Display Version
To display the system’s software and hardware versions:
From the Service menu, select Version [710]; the hardware (HW) and software (SW) versions are
displayed.
4.8.12. Enable Programming
The Enable Programming command enables a user with Master code authorization to grant access to system
programming. This feature is relevant only if the Installer Access and/or the RP Access options are programmed as
"User Initiated" – see p. 62, 9.14 Installer Access and p. 69, RP Access Options.
To grant access to the installer or Remote Programmer:
From the Service menu, select Enable Prog. [711]; a 30-minute time window is opened during which
the Installer Code is valid or RP communication may be established.
4.8.13. Global Chime
The Chime feature causes the Control System’s built-in siren to ring when specific zones are triggered. Using the
Global Chime option, you can enable or disable this feature for all zones that are defined as Chime enabled – see p.46,
7.3.5 Chime.
To enable or disable Global Chime:
1. From the Service menu, select Global Chime [712].
2. Select either Enabled or Disabled.
Note: Though the Service menu is accessible to the Master and Installer only, Global Chime can also be
accessed via a convenient shortcut without needing to enter a valid user code. To access the Global
Chime option from Standby mode, press then .
4.8.14. Remote Firmware Update
The Remote Firmware Update command enables a user with Master code authorization to initiate the update. This
feature is relevant only if the Remote Firmware Update mode is programmed as "User Initiated" – see p. 74, 10.8.4
Remote Firmware Update
To grant access to Remote Firmware Update:
From the Service menu, select, SW Update [713]; a 24-hours time window is opened during which the
Remote Firmware Update may be performed.
4.8.15. IP Display
When using Ethernet connection, you can view the LAN IP address of the Control System.
To display the IP Address:
From the Service menu, select IP Display [714]; the LAN IP address of the Control System is displayed.