9 System Options
iConnect Installation Manual
61
Note: When the Guard Code Report option is enabled, the Guard Code option [9408] must be disabled.
To Activate the Guard Code Control option:
1. From the Programming menu, select System Options, Guard Code, Guard Code CT, Guard Code Rep
[94222].
2. Select Enabled or Disabled.
9.9. "No Arm" Indication
The "No Arm" indication is a feature designed to inform the central station that the system has not been armed for a
specified period of time.
To define the "No Arm" indication interval:
1. From the Programming menu, select System Options, No Arm Ind. [9409].
2. Select 1 Week, 2 Weeks, 3 Weeks, 4 Weeks or Disabled.
Note: The No Arm event message is an unclassified event. This means that it does not belong to any event
group. If the No Arm option is programmed with any option other than "Disabled", the event message
will be sent.
9.10. Jamming Detection
The system is able to detect RF Jamming that is usually caused by an intruder attempting to compromise the
security system.
To program the Jamming Detection setting:
1. From the Programming menu, select System Options, Jamming Det. [9410].
2. Select Enabled or Disabled.
9.11. "No Motion" Time
The No Motion feature is designed to monitor the activity of disabled or elderly people. If a sensor defined as "No
Motion" (see p. 45, 7.3.1 Zone Type) has not detected within a pre-defined period of time, a No Motion event message is
sent to the central station.
To program the No Motion time:
1. From the Programming menu, select System Options, No Motion [9411].
2. Enter the No Motion time value between 00:00 and 72:00. To disable the No Motion feature, enter 00:00.
Press .
9.12. Microphone/Speaker Options
In addition to the built-in microphone and speaker, the iConnect Control System Control System supports an external
microphone/speaker unit called Interphone. The Microphone/Speaker option allows you to choose which microphone
and speaker are in use. You can choose one mic./speaker (internal or external) to function exclusively or both may
function simultaneously.
To program the Microphone/Speaker option:
1. From the Programming menu, select System Options, Mic./Speaker [9412].
2. Select Internal, External or Internal & External.
9.13. Vocal Messages
The Vocal Messages option allows you to enable/disable vocal annunciation of system status. When this feature is
enabled, the system plays a short message to announce events such as arming and disarming.
To program the Vocal Messages option:
1. From the Programming menu, select System Options, Vocal Message [9413].
2. Select Enabled or Disabled.
Note: The availability of the Vocal Message annunciation feature is hardware dependent.