10 Communications
iConnect Installation Manual
68
10.3.2. Protocol
To program voice report protocol:
1. From the Programming menu, select Communications, Accounts [951].
2. Select the account you want to program (2-6).
3. From the account’s sub-menu, select Protocol [#2].
4. Select Voice Report.
10.3.3. Communication Interface
For each Vocal Message account, you can choose whether the system employs cellular or PSTN communication.
To program a Voice Report Account’s communication interface:
1. From the Programming menu, select Communications, Accounts [951].
2. Select the account you want to program (2-6).
3. From the account’s sub-menu, select Interface [#3].
4. Select GSM or PSTN.
10.3.4. Two-Way Audio
The Two-Way audio option determines whether Two-Way Audio is enabled for the Voice Report Account. For further
information, see p. 39, 5.2.3 Two-Way Audio after Vocal Messages.
To program the Two-Way Audio option for a Voice Report Account:
1. From the Programming menu, select Communications, Accounts [951].
2. Select the account you want to program (2-6).
3. From the account’s sub-menu, select Two-Way Audio [#4].
4. Select Enabled or Disabled.
10.3.5. Home ID
The Home ID is a short message that is played at the beginning of a vocal message call in order to identify the system
to the user. For example, at the beginning of the vocal message call, the message "Michael’s House" will be played
before the event messages.
To play back the Home ID message:
From the Programming menu, select Communications, Accounts, Home ID, Play Message [95181].
To record a Home ID message:
1. From the Programming menu, select Communications, Accounts, Home ID, Record Message [95182].
2. Press to start recording the message.
3. Record your message. The message may be up to ten seconds long.
4. Press to stop recording; the message is automatically played back and OK? is displayed. Press to
save your recording.
10.4. Remote Programming
Electronics Line 3000’s Remote Programmer (RP) and WEB Remote Programmer software enable you to operate and
program the system from a PC either on-site or from a remote location. The software provides a comprehensive
interface to the iConnect Control System designed to facilitate programming. There are 3 access levels available:
Supervisor (full access), Technician (limited access to the program, a technician is not able to view or change user codes
or the RP access code), and Operator (access to user operations, such as arming and disarming the system).
10.4.1. Remote Programmer
PC to Control System Connection Methods
You can connect to the Control System from a PC using one of three methods:
Direct Call: The RP calls the site, the system picks up and RP communication is established.

Table of Contents