9.17.2. Tamper Behavior
Opening of any tamper switch while the Control System is disarmed causes the Control System to send an alert. If
the EN-50131 standard is chosen, the siren is not activated in this case. For other standards (Skafor, Regular), the
siren is activated.
9.17.3. Number of Events From Single Source
The EN-50131 standard requires that the system avoid multiple events being generated from a single source. The
number of repeated events from the same source during any Arm or Disarm period is limited to three. Two kinds of
event types are defined for each device: Alarm/Tamper event and fault/trouble event. Every device can have maximum
of three events from each type registered in the log. After the third event from the same source, no more events are sent
to CS. Counters are reset each time the system is armed or disarmed.
9.17.4. EN-50131 Required Settings
To meet the requirements of the EN-50131 standard:
Set Supervision Time to 2 hours – see p.44, 7.2.3 Supervision Time;
Set Supervised Arm to 20 minutes – see p. 56, 9.3.3 Supervised Arm;
Set Entry Delay to 45 sec. maximum – see p. 53, 8.1 Entry/Exit Delay;
Set Arm Status Display to 30 sec. -- see p. 58, 9.6.1 Arm Status Display;
Set Entry/Exit Trouble to "Enabled" – see p. 63, 9.18 Entry/Exit Trouble.
9.18. Entry/Exit Trouble
If this function is enabled, the system can't be armed when the Exit Delay expires, if one of the following
conditions is present:
An entry/exit zone is open;
Tamper Alarm from a zone during exit (if not restored before the exit delay expires);
Zone Active when Exit Delay expires.
The event is then sent to the central station account.
To program the Entry/exit Trouble option:
1. From the Programming menu, select System Options, Entry Exit TR [9418].
2. Select Enabled or Disabled.
9.19. Report Fail Trouble
If the Report Fail Trouble option is enabled, failure to report an event displays System Trouble on the LCD display.
Report Fail Trouble is displayed after the control system has exhausted all message attempts and report cycles when
trying to report the event. To restore a System Trouble condition caused by failure to report, press until you have
scrolled through the entire system trouble list. If the Report Fail Trouble is disabled, failure to report an event does not
cause a system trouble condition.
To program the Report Fail Trouble option:
1. From the Programming menu, select System Options, Rep. Fail Trb. [9419].
2. Select Enabled or Disabled.
9.20. Immediate Arming from WUApp
If immediate arming from WUApp is enabled, all WEB Arm commands received are executed immediately regardless
of the programmed Exit Delay – see p. 53, 8.1 Entry/Exit Delay. If disabled, the ARM commands will be executed with
the programmed Exit Delay.
1. From the Programming menu, select System Options, WEB Immed. Arm [9420].
2. Select Enabled or Disabled.