7 Devices
iConnect Installation Manual
52
7.8.1. Smartkey Type
You can define each registered smartkey as Controlled or Non-controlled. A Controlled smartkey causes the system to
send arm/disarm event messages to the central station. Non-controlled smartkeys never send arm messages and send a
disarm message only if the system is disarmed after an alarm occurrence.
To program the smartkey type:
1. From the Programming menu, select Devices, Smartkeys [918].
2. Select the smartkey you want to program.
3. From the smartkey’s sub-menu, select Type [#2]; the current setting is displayed.
4. Select Controlled or Non-controlled.
7.8.2. Partition Set
In partitioned systems, there is an option to assign each Smartkey specifically to partition one, partition two, or to full
arming.
To program the Partition Set option:
1. From the main menu, select Devices, Smartkeys [918].
2. Select the Smartkey you want to program.
3. From the Smartkey sub-menu, select Partition Set [#4]; the current Partition Set is displayed.
Partition Set Description
123 (F + P1 + P2) The Smartkey is assigned to both partitions
and full arming.
2 (P1) The Smartkey is assigned to partition 1.
3 (P2) The Smartkey is assigned to partition 2.
Table 7-5: Smartkey Partition Set
4. Use the keys 1, 2 and 3 to toggle the current setting.
Note: If you assign the Smartkey to both partitions, assign it to the full arming also.