EasyManua.ls Logo

EMC2 VNX5500 - VNX5500 Site Requirements

Default Icon
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
EMC VNX5500 File Installation Guide
Site requirements
Table 2 Resource requirements
Resource Requirement
Power AC: For high availability, at least two 110 or 240 V AC circuits are required.
or
DC: See the requirements in
DC-Powered VNX Series Enclosures Installation and Operation
Guide.
Network One or two 1-Gigabit Ethernet management connections (depending on 1 or 2 Control
Stations) and two customer-supplied CAT5e or better cables.
Space Cabinet vertical space:
3U for disk processor enclosure (DPE)
1U for the standby power supply (SPS)
1U for each Control Station (CS)
2U for each blade enclosure (BE)
For each optional DAE, either 2U or 3U
Tools Slotted- or Phillips-head screwdriver
Management Station A Windows-based computer to run the initialization, maintenance, and management tools
with:
Minimum screen resolution of 1280 x 800
At least 500 MB of free space
Connection on same LAN subnet as your VNX5500 system
DNS/NTP server network connection to the VNX5500 and the management host
Windows Domain Controller recommended
SMTP server network connection to the VNX5500 and the management host
•JRE*
Browser * (Internet Explorer or Mozilla Firefox)
*Supported versions are listed in the release notes.
Network information The management port and login information in the Planning Worksheets of this install guide.
This information includes:
A static IP address for each storage processor in the system (for example,
http://123.45.6.7)
The IPv6 global prefix and gateway for each SP if your network supports the IPv6 Internet
Protocol and you want to manually configure IPv6 for the management ports
The subnet mask of the LAN to which the system is connected
The default gateway address of the LAN to which the system is connected

Table of Contents

Related product manuals