For IS parameters, see Product certifications.
External Supply Voltage:
Passive Non-IS: 7.2 - 35 Vdc
Passive IS: 8.7 – 30 Vdc
Maximum Output Voltage (open loop):
Active Non-IS: 24 Vdc
Active IS: 23 Vdc
HART master:
Maximum 5 HART Slave Devices (Passive)
Maximum 3 HART Slave Devices (Active)
Figure A-1: Loop Resistance: Passive Non-IS Analog Input
%
$











$
A. Loop resistance [Ω]
B. External power supply voltage [V]
Max Loop Resistance
(14)
@ 23 mA = 43.4 * (External Power Supply Voltage -7.2) [Ω]
(14) Any sense resistance must be subtracted from calculated max loop resistance to receive the maximum cable resistance.
Reference Manual Specifications and reference data
00809-0100-2410 December 2019
Rosemount 2410 Tank Hub 115