B.4.2 E6 Canada Explosion-proof
Certificate
FM16CA0068X
Standards
CSA C22.2 No 0.4:2017
CSA C22.2 No. 0.5:2016
CSA C22.2 No. 30-M1986:1986 (Reaffirmed 2016)
CSA C22.2 No. 94-M91:1991 (Reaffirmed 2011)
CSA C22.2 No. 1010.1:2004 (Reaffirmed 2009)
CAN/CSA 60079-0:2015
CAN/CSA 60079-1:2016
CSA C22.2 60079-7:2016
CAN/CSA 60079-11:2014
CSA C22.2 No. 60529:2016
Markings
FISCO
For b = Tank Bus (Fieldbus - Power and Communication): F and when d =
Secondary Communication Bus (Non-IS): R, E, 5, K, L, V, H, G, A, U, T, B,
6, 7, 0, or F: FISCO POWER SUPPLY XP CL 1, DIV 1 GPS C, D & Associated
Apparatus providing IS circuit to CL I, DIV 1, GPS C & D; DIP CL II/III, DIV.
1, GP E, F & G; CL I, ZONE 1 Ex db eb [ib] IIB Amb. Temp. Limits -50°C to
+70°C Temp. Class T4 SEE CONTROL DRAWING D9240040-901 Type 4X;
IP66/67
Markings
FISCO HART
active
When b = Tank Bus (Fieldbus - Power and Communication): F and when
d = Secondary Communication Bus (HART
®
/4-20mA Active IS Input/
Output): W, C or 8: FISCO POWER SUPPLY XP CL 1, DIV 1 GPS C, D &
Associated Apparatus providing IS circuit to CL I, DIV 1, GPS C & D; DIP
CL II/III, DIV. 1, GP E, F & G; CL I, ZONE 1 Ex db eb [ib] IIB ENTITY IS I/O
ACTIVE: XP CL 1, DIV 1 GPS C, D & Associated Apparatus providing IS
circuit to CL 1, DIV 1, GPS C & D ACTIVE: CL I, ZONE 0 Ex db eb [ ia IIC ] IIB
Amb. Temp. Limits -50°C to +70°C Temp. When b = Tank Bus (Fieldbus -
Power and Communication): F and when d = Secondary Communication
Bus (HART
®
/4-20mA Passive IS Input/Output): D or 9. Class T4 SEE
CONTROL DRAWING D9240040-901 Type 4X; IP66/67
Markings
FISCO HART
passive
When b = Tank Bus (Fieldbus - Power and Communication): F and when
d = Secondary Communication Bus (HART
®
/4-20mA Passive IS Input/
Output): D or 9: FISCO POWER SUPPLY XP CL 1, DIV 1 GPS C, D &
Associated Apparatus providing IS circuit to CL I, DIV 1, GPS C & D; DIP
CL II/III, DIV. 1, GP E, F & G; CL I, ZONE 1 Ex db eb [ib] IIB ENTITY IS I/O
PASSIVE: CL I, ZONE 1 Ex db eb ib IIB Amb. Temp. Limits -50°C to +70°C
Temp. Class T4 SEE CONTROL DRAWING D9240040-901 Type 4X;
IP66/67
Markings
Entity
When b = Tank Bus (Fieldbus - Power and Communication): E and when
d = Secondary Communication Bus (Non-IS): R, E, 5, K, L, V, H, G, A, U, T,
B, 6, 7, 0, or F: ENTITY IS POWER SUPPLY XP CL I, DIV 1 GPS C, D &
Associated Apparatus providing IS circuit to CL I, DIV 1, GPS C & D; DIP
CL II/III, DIV. 1, GP E, F & G; CL I, ZONE 1 Ex db eb [ib] IIB Amb. Temp.
Limits -50°C to +70°C Temp. Class T4 SEE CONTROL DRAWING
D7000002-611 Type 4X; IP66/67