Maintenance 3-17
CadJet 3D Service Manual
MAINTENANCE
The Slide Shaft is set to 1.418” (36cm) from the top of the Slide Shaft to
the Platen surface for these printers. The normal operating range for
the height of the Slide Shaft is between 1.390” (35.3cm) to 1.440”
(36.6cm).
You will need the following:
· Height Gauge Kit Assembly
· 1/4" open and box end wrench (.110” thick)
Height Gauge (Alignment) Kit Contents are:
Dial Gauge Micrometer
Modified Novajet Cartridge for newer products
Modified Novajet 4/Pro/Pro 50 Cartridge - Not Used
Platen/Carriage Shaft Mounting Block
Calibration Jo Block (1.434”) - Not used
Plastic Gauge Card (0.011”) - Not used
There are two basic measurements that are to be made using
this kit (ensure power is off prior to performing these procedures):
1. Slide Shaft Profile Adjustment
2. Carriage (Cartridge) Head Height Setting
1. Connect the dial gauge micrometer to the Shaft mounting
block as shown in Figure 3-10.
Figure 3-10. Dial Gauge Micrometer Assembly.