Electrical connection Gammapilot FMG50
34 Endress+Hauser
5.9.2 Connection of the HART device and RIA15 with backlighting
Y
I
R
s
DC
1
2
3
LED
-
+
A0019568
 7 Block diagram of HART device with RIA15 process indicator with light
1 Device with HART communication
2 Power supply
3 HART resistor
5.9.3 FMG50, RIA15 with installed HART communication resistor
module
The HART communication module for installation in the RIA15 can be ordered
together with the device.
Product structure, feature 620 "Accessory enclosed":
Option PI "HART communication resistor for RIA15"
The voltage drop to be taken into account is:
Max. 7 V
Alternatively available as an accessory, for details see Technical Information
TI01043K and Operating Instructions BA01170K
Connection of the HART communication resistor module, RIA15 without backlighting
1
LED
-
+
3
2
Y
I
R
s
DC
A0020839
 8 Block diagram of HART device, RIA15 without light, HART communication resistor module
1 HART communication resistor module
2 Device with HART communication
3 Power supply