Commissioning Gammapilot FMG50
82 Endress+Hauser
7.6 Operation and settings via RIA15
See the RIA15 Operating Instructions, BA01170K
7.7 Data access - Security
7.7.1 Locking via password in FieldCare / DeviceCare / SmartBlue
The Gammapilot FMG50 can be locked and unlocked via a password (see the "Software
locking" section)
7.7.2 Hardware locking
The Gammapilot FMG50 can be locked and unlocked via a switch on the main unit.
Hardware locking can only be unlocked via the main unit (flip the switch). It is not possible
to unlock the hardware by communication.
7.7.3 Bluetooth® wireless technology (optional)
Signal transmission via Bluetooth® wireless technology uses a cryptographic
technique tested by the Fraunhofer Institute
The device is not visible via Bluetooth® wireless technology without the SmartBlue App.
Only one point-to-point connection between one sensor and one smartphone or tablet is
established.
The Bluetooth® wireless technology interface can be deactivated via SmartBlue,
FieldCare or DeviceCare.
The Bluetooth® wireless technology interface can be reactivated via FieldCare or
DeviceCare.
It is not possible to reactivate the Bluetooth® wireless technology interface via the
SmartBlue App.
7.7.4 RIA15 locking
The device setup can be locked with a 4-digit user code
Additional information is available in the Operating Instructions for the RIA15
7.8 Overview of the operating menu
A complete overview of the operating menu is provided in the "Description of Device
Parameters" documentation.