Description of device parameters (operating menu) Levelflex FMP51, FMP52, FMP54
114 Endress+Hauser
Navigation
Display/operation ® Format display
Setup ® Advanced Setup ® Display ® Format display
Description
Use this function to select how the measured value is shown on the local display. The display
format (size, bar graph etc.) and number of measured values displayed simultaneously (1 to 4) can
be configured. This setting only applies to normal operation.
• The Value 1 display - Value 4 display parameters are used to specify what measured
values are shown on the display and in what order (® ä 161).
•
If more measured values are specified than the display mode selected permits, the values
alternate on the device display. The display time until the next change is configured using
the Display interval parameter (® ä 116).
Options
• 1 value, max. size
•
1 bargraph + 1 value
• 2 values
• 1 value large + 2 values
• 4 values
Factory setting
1 value, max. size