Important document information Levelflex FMP51, FMP52, FMP54
6 Endress+Hauser
51 52 54 Feature
010
Approval Safety Instructions
HART
Safety Instructions
PROFIBUS
FOUNDATION Fieldbus
x CD CSA C/US DIP Cl.I,II Div.1 Gr.E-G XA00529F XA00570F
x x x C2 CSA C/US IS Cl.I,II,III Div.1 Gr.A-G, NI Cl.1 Div.2, Ex ia XA00530F XA00571F
x x x C3 CSA C/US XP Cl.I,II,III Div.1 Gr.A-G, NI Cl.1 Div.2, Ex d XA00529F XA00570F
x x x FB FM IS Cl.I,II,III Div.1 Gr.A-G, AEx ia, NI Cl.1 Div.2 XA00531F XA00573F
x x x FD FM XP Cl.I,II,III Div.1 Gr.A-G, AEx d, NI Cl.1 Div.2 XA00532F XA00572F
x FE FM DIP Cl.II,III Div.1 Gr.E-G XA00532F XA00572F
x x x IA IECEx Zone 0 Ex ia IIC T6 Ga XA00496F XA00516F
x x x IB IECEx Zone 0/1 Ex ia IIC T6 Ga/Gb XA00496F XA00516F
x x x IC IECEx Zone 0/1 Ex d[ia] IIC T6 Ga/Gb XA00499F XA00519F
x x x ID IECEx Zone 0/2 Ex ic[ia] IIC T6 Ga/Gc XA00497F XA00517F
x IE IECEx Zone 20 Ex t[ia] IIIC Txx°C Da IP6x XA00501F XA00521F
x IF IECEx Zone 20/21 Ex t[ia] IIIC Txx°C Da/Db IP6x XA00501F XA00521F
x x x IG IECEx Zone 2 Ex nA IIC T6 Gc XA00498F XA00518F
x x x IH IECEx Zone 2 Ex ic IIC T6 Gc XA00498F XA00518F
x x x IL IECEx zone 0/2 Ex nA(ia) IIC T6 Ga/Gc XA00497F XA00517F
x x x I2 IECEx zone 0/1 Ex ia IIC T6 Ga/Gb, zone 20/21 Ex ia IIIC A20/21 IP6x,
Da/Db
XA00502F XA00522F
x x x I3 IECEx Zone 0/1 Ex d[ia] IIC T6 Ga/Gb, Zone 20/21 Ex t[ia] IIIC Txx°C
Da/Db IP6x
XA00503F XA00523F
x x x NA NEPSI Zone 0 Ex ia IIC T6 Ga XA00634F XA00640F
x x x NB NEPSI Zone 0/1 Ex ia IIC T6 Ga/Gb XA00634F XA00640F
x x x NC NEPSI Zone 0/1 Ex d(ia) IIC T6 Ga/Gb XA00636F XA00642F
x NF NEPSI Zone 20/21 tD IIIC A20/21 IP6x Da/Db XA00637F XA00643F
x x x NG NEPSI Zone 2 Ex nA II T6 Gc XA00635F XA00641F
x x x NH NEPSI Zone 2 Ex ic IIC T6 Gc XA00635F XA00641F
x x x N2 NEPSI zone 0/1 Ex ia IIC T6 Ga/Gb, zone 20/21 Ex iaD 20/21 T* XA00638F XA00644F
x x x N3 NEPSI zone 0/1 Ex d(ia) IIC T6 Ga/Gb, DIP A20/21 T* IP66 XA00639F XA00645F
x x x 8A FM/CSA IS+XP Cl.I,II,III Div.1 Gr.A-G XA00531F
XA00532F
XA00572F
XA00573F
For certified devices the relevant Safety Instructions (XA) are indicated on the nameplate.
1.2
Document conventions
1.2.1 Safety symbols
Symbol Meaning
DANGER
A0011189-EN
DANGER!
This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious
or fatal injury.
WARNING
A0011190-EN
WARNING!
This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious
or fatal injury.

Table of Contents

Other manuals for Endress+Hauser Levelflex FMP53

Related product manuals