EasyManua.ls Logo

Endress+Hauser Levelflex FMP53 - Turning the Transmitter Housing

Endress+Hauser Levelflex FMP53
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Levelflex FMP51, FMP52, FMP54 Mounting
Endress+Hauser 55
A
B
6Nm
6Nm
6Nm
6Nm
r
min
=100mm(4
”)
r
min
=100mm(4”)
3m(9ft)
3m(9ft)
A0014794
å 14
Connecting the cable. There are the following possibilities:
A Angled plug at the probe
B Angled plug at the electronics housing
6.3.6 Turning the transmitter housing
To provide easier access to the connection compartment or display module, the transmitter
housing can be turned:
max.350°
8mm
8mm
A0013713
1. Unscrew the securing screw using an open-ended wrench.
2. Rotate the housing in the desired direction.
3. Firmly tighten the securing screw. (1,5 Nm for plastics housing; 2,5 Nm for aluminium or
stainless steel housing).