EasyManua.ls Logo

Endress+Hauser Levelflex FMP53 - FMP52: Dimensions of Process Connection and Probe

Endress+Hauser Levelflex FMP53
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Levelflex FMP51, FMP52, FMP54 Mounting
Endress+Hauser 31
6.1.5 FMP52: Dimensions of process connection and probe
A
B C
D E F
81.55
(3.21)
ø16
0.63)
ø63.9
2.52)
81.55
(3.21)
ø90.89
3.58)
ø16
0.63)
82.95
(3.27)
ø59.8
(ø2.35)
ø16
0.63)
116.4 (4.58)
ø59.8
(ø2.35)
ø16
0.63)
ø50.42
.99)(ø1
G
H
ø16
0.63)
ø4
0.16)
110
)(4.33
ø37
)(ø1.46
ø16
0.63)
118 .65)(4
LN
ø22
0.87)
mm (in)
R
122
(4.8)
52
(2.05)
50
(1.97)
61
(2.4)
ø82.5
(ø3.25)
82.95
(3.27)
ø68.5
2.7)
ø16
0.63)
r
min
= 100 (4)
43
(1.7)
A0012757
A Mounting bracket for probe design "Sensor remote" (Feature 600)
B Tri-Clamp 1-1/2" (Feature 100)
C Tri-Clamp 2" (Feature 100)
D Tri-Clamp 3" (Feature 100)
E DIN 11851 (Dairy coupling) DN50 (Feature 100)
F Flange ANSI B16.5, EN1092-1, JIS B2220 (Feature 100)
G Rod probe 16mm or 0.63 in , PFA>316L (Feature 060)
H Rope probe 4mm or1/6", PFA>316 (Feature 060)
LN Length of probe
R Reference point of the measurement

Table of Contents