Trouble shooting Levelflex FMP51, FMP52, FMP54
88 Endress+Hauser
A0014014-EN
Calling up remedial measures
1. Navigate to the "Diagnostics" menu.
Ã
In the "Actual diagnostics" parameter, the diagnostic event is shown with event text.
2. On the right in the display range, hover the cursor over the "Actual diagnostics" parameter.
Ã
A tool tip with remedial measures for the diagnostic event appears.
11.4
Diagnostic list
In the Diagnostics list submenu, up to 5 currently pending diagnostic messages can be
displayed. If more than 5 messages are pending, the messages with the highest priority are shown
on the display.
Navigation path
Diagnostics ® Diagnostics list
Diagnostics
/../Diagnoselist
Diagnostics3
Diagnostics2
F273Mainelectronic
A0014006-EN
Calling up and closing the remedial measures
1.
Press F.
Ã
The message for the remedial measures for the selected diagnostic event opens.
2.
Press S + O simultaneously.
Ã
The message about the remedial measures closes.