Mounting Levelflex FMP51, FMP52, FMP54
32 Endress+Hauser
6.1.6 FMP54: Dimensions of process connection and probe
A
B
C D E
SW60
AF60
SW14
AF14
M40x1
316.6 (12.5)
37
(1.46)
ø90
(ø3.54)
SW14
AF14
M40x1
341.8 (13.5)
ø90
(ø3.54)
SW14
AF14
M40x1
277.9 (10.9)
ø90
(ø3.54)
SW14
AF14
SW60
AF60
M40x1
37
(1.46)
250.9 (9.88)
ø90
(ø3.54)
F
H
I
LN
500 (19.7)
SW14
AF14
SW14
AF14
SW14
AF14
SW14
AF14
SW14
AF14
SW14
AF14
1000 (39.4)
2,2
(0.09)
150 (5.91)
12 (0.47)
4 (0.16)
ø22 (ø0.87)
ø75 (ø2.95)
ø29 (ø1.14)
ø42.4
(ø1.67)
mm (in)
ø16
(ø0.63)
ø16
(ø0.63)
ø4
(ø0.16)
ø4
(ø0.16)
min. 50 (1.97)
max. 1051 (41.4)
M14
20 (0.79)
G
J
R
122
(4.8)
52
(2.05)
50
(1.97)
61
(2.4)
ø82.5
(ø3.25)
M
L
L
L
N
N
M M
A0012778
A Mounting bracket for probe design "Sensor remote" (Feature 600)
B Thread ISO228 G1-1/2 or ANSI MNPT1-1/2; XT 280 °C (Features 100 and 090)
C Flange ANSI B16.5, EN1092-1, JIS B2220; XT 280 °C (Features 100 and 090)
D Thread ISO228 G1-1/2 or ANSI MNPT1-1/2; HT 450 °C (Features 100 and 090)
E Flange ANSI B16.5, EN1092-1, JIS B2220; HT 450°C (Features 100 and 090)
F Rope probe 4mm or 1/6" (Feature 060)
G Rope probe 4mm (1/6"), centering disk optional (Features 060 and 610)
H Rod probe 16mm or 0.63in; centering disk optional, see table below (Features 060 and 610)
I Rod probe 16mm or 0.63in ; 20" or 40" divisible; centering disk optional, see table below (Feature 060 and 610)