Levelflex FMP51, FMP52, FMP54 Mounting
Endress+Hauser 45
For mechanical reasons, the probe should be installed as vertically as possible.
With inclined installations the probe length has to be adjusted in dependence to the installation
angle.
Up to LN = 1 m (3.3 ft): a = 30°
Up to LN = 2 m (6.6 ft): a = 10°
Up to LN = 4 m (13.1 ft): a = 5°
Non-metallic vessels
1
2
A0012527
1 Non-metallic vessel
2 Metal sheet or metal flange
To measure, Levelflex with a rod probe needs a metallic surface at the process connection.
Therefore:
Select an instrument version with metal flange (minimum size DN50/2").
Or: mount a metal sheet with a diameter of at least 200 mm (8") to the probe at the process
connection. Its orientation must be perpendicular to the probe.
No additional measures are required for coax probes.
Plastic or glass tanks: Mounting the probe externally at the wall
1
2
a
3
A0014150
1 Plastic or glass tank
2 Metall sheet with threaded sleeve
3 No free space between tank wall and probe!