Micropilot FMR56, FMR57 FOUNDATION Fieldbus Integration into a FOUNDATION Fieldbus network
Endress+Hauser 65
9.6.1 Setup Transducer Block
Name Label Index Data type Size (Bytes) Storage Class Write access MODE_BLK
operating_mode Operating mode 15 ENUM16 2 Static Maintenance OOS
distance_unit Distance unit 16 ENUM16 2 Static Maintenance OOS
tank_type Tanktyp 17 ENUM16 2 Static Maintenance OOS
tube_diameter Tube diameter 18 FLOAT 4 Static Maintenance OOS
bin_type Bin type 19 ENUM16 2 Static Maintenance OOS
solid_filling_speed_range Max. filling speed solid 20 ENUM16 2 Static Maintenance OOS
solid_draining_speed_rang
e
Max. draining speed solid 21 ENUM16 2 Static Maintenance OOS
medium_group Medium group 22 ENUM16 2 Static Maintenance OOS
empty_calibration Empty calibration 23 FLOAT 4 Static Maintenance OOS
full_calibration Full calibration 24 FLOAT 4 Static Maintenance OOS
level_unit_ro Level unit 25 ENUM16 2 Static Maintenance OOS
PrimLevOut Primary Value 26 Standard 5 Dynamic
output_unit_after_lineariza
tion
Unit after linearization 27 ENUM16 2 Static Maintenance
filtered_distance Distance 28 Standard 5 Dynamic
signal_quality Signalqualität 29 ENUM16 2 Dynamic
confirm_distance Confirm distance 30 ENUM16 2 Static Maintenance OOS
mapping_start_point Mapping start point 31 FLOAT 4 Static Maintenance OOS
mapping_end_point Mapping end point 32 FLOAT 4 Static Maintenance OOS
end_map_ampl End map amplitude 33 FLOAT 4 Static Maintenance OOS
map_end_x Present mapping 34 FLOAT 4 Dynamic
map_end_y Map end Y 35 FLOAT 4 Dynamic
record_map Record map 36 ENUM16 2 Static Maintenance OOS
prepare_recording_map Prepare recording map 37 ENUM16 2 Static Development OOS
end_of_mapping End of mapping 38 ENUM16 2 Static Maintenance OOS
empty_scale 39 FLOAT 4 Static Maintenance OOS
full_scale 40 FLOAT 4 Static Maintenance OOS
empty_distance Tank/silo height 41 FLOAT 4 Static Maintenance OOS
sw_option_active_overview Software option overview 42 BIT_ENUM32 4
sensor_type_ro Sensor type 43 ENUM16 2 Static Service OOS
medium_type Medium type 44 ENUM16 2 Static Service OOS
decimal_places_menu Decimal places menu 45 ENUM16 2 Static Maintenance AUTO
evaluation_mode_ro Evaluation mode 46 ENUM16 2 Dynamic Maintenance OOS
access_status_tooling Access status tooling 47 ENUM16 2 Dynamic
locking_status Locking status 48 BIT_ENUM16 2 Dynamic
9.6.2 Advanced Setup Transducer Block
Name Label Index Data type Size (Bytes) Storage Class Write access MODE_BLK
medium_type Medium type 15 ENUM16 2 Static Service OOS
medium_property Medium property 16 ENUM16 2 Static Maintenance OOS

Table of Contents