Micropilot FMR56, FMR57 FOUNDATION Fieldbus Commissioning (block-based operation)
Endress+Hauser 85
Step Block Parameter Action
5 SETUP (TRDSUP) Empty calibration
(empty_calibration)
Enter the distance E between the
reference point R and the minimum level
(0%).
6 SETUP (TRDSUP) Full calibration (full_calibration) Enter distance F between the minimum
(0%) and maximum (100%) level.
7 SETUP (TRDSUP) Level (level) Displays the measured level L.
8 SETUP (TRDSUP) Distance (filtered_dist_val) Displays the distance D between the
reference point R and the level L.
9 SETUP (TRDSUP) Signal quality (signal_quality) Displays the signal quality of the level
echo.
10 SETUP (TRDSUP) Confirm distance
(confirm_distance)
Compare the displayed distance to the real
distance in order to start the recording of
the mapping curve.
Selection:
179: Manual map
32847: Factory map
32859: Distance ok
32860: Distance too big
32861: Distance too small
32862: Distance unknown
33100: Tank empty
12.6 Configuration of the on-site display
12.6.1 Factory settings of the on-site display for level measurements
Parameter Factory setting
Format display 1 value, max. size
Value 1 display Level linearized
Value 2 display None
Value 3 display None
Value 4 display None
The on-site display can be adjusted in the DISPLAY (TRDDISP) transducer block.
12.7 Configuration management
After commissioning, you can save the current device configuration, copy it to another
measuring point or restore the previous device configuration. You can do so using the
Configuration management parameter and its options.
Navigation path in the operating menu
Setup → Advanced setup → Conf.backup disp → Config. managem.
Block operation
Block: DISPLAY (TRDDISP)
Parameter: Configuration management (configuration_management)