Integration into a FOUNDATION Fieldbus network Micropilot FMR56, FMR57 FOUNDATION Fieldbus
70 Endress+Hauser
9.6.6 Expert Information Transducer Block
The parameters of the Expert Information Transducer Block are described in
GP01017F: "Micropilot FMR5x - Description of Device Parameters - FOUNDATION
Fieldbus"
Name Label Index Data type Size (Bytes) Storage Class Write access MODE_BLK
abs_echo_ampl Absolute echo amplitude 15 Standard 5
rel_echo_ampl Relative echo amplitude 16 Standard 5 Dynamic
rel_eop_ampl Tank bottom echo amplitude 17 Standard 5 Dynamic
noise_signal_val Noise of signal 18 FLOAT 4 Dynamic
electronic_temperature Electronic temperature 19 Standard 5 Dynamic
found_echoes Found echoes 20 ENUM16 2 Dynamic
temperature_unit Temperature unit 21 ENUM16 2 Static Maintenance OOS
max_electr_temp Max. electronic temperature 22 FLOAT 4 Static Development AUTO
application_parameter Application parameter 23 ENUM16 2 Dynamic
time_max_electr_temp Time max. electronics temperature 24 STRING 14 Dynamic
measurement_frequency Measurement frequency 25 FLOAT 4 Dynamic
min_electr_temp Min. electronics temperature 26 FLOAT 4 Static Development AUTO
time_min_electr_temp Time min. electronics temperaturer 27 STRING 14 Dynamic
reset_min_max_temp Reset min/max. Temp. 28 ENUM16 2 Static Service AUTO
used_calculation Used calculation 29 ENUM16 2 Dynamic
tank_trace_state Status Tanktrace 30 ENUM16 2 Dynamic
max_draining_speed Max. draining speed 31 FLOAT 4 Static Development AUTO
max_filling_speed Max. filling speed 32 FLOAT 4 Static Entwicklung AUTO
time_max_level Time max. level 33 STRING 14 Dynamic
max_level_value Max. level value 34 FLOAT 4 Static Development AUTO
time_min_level Time min. level 35 STRING 14 Dynamic
min_level_value Min. level 36 FLOAT 4 Static Development AUTO
reset_min_max Reset min./max. 37 ENUM16 2 Static Service AUTO
appl_param_changed_flags Application parameter 38 UINT16 2 Static Production AUTO
terminal_voltage_ds Terminal voltage 39 Standard 5 Dynamic
area_of_incoupling Area of incoupling 40 Standard 5 Dynamic
linearization_type_ro Linearization type 41 ENUM16 2 Static Maintenance OOS
operating_mode Operating mode 42 ENUM16 2 Static Maintenance OOS
decimal_places_menu_ro Decimal places menu 43 ENUM16 2 Static Maintenance AUTO
activat_sw_option Activate SW option 44 UINT32 4 Static Maintenance AUTO
sw_option_active_overview Sw option active overview 45 BIT_ENUM32 4 Dynamic
debug_status 107 UINT8 1 Dynamic x AUTO
9.6.7 Service Sensor Transducer Block
The parameters of the Service Sensor Transducer Block can only be operated by
authorized Endress+Hauser service personnel.