Commissioning Proline Promass E 100 Modbus RS485
58 Endress+Hauser
Linear expansion coefficient
Square expansion coefficient
Parameter overview with brief description
Parameter Prerequisites Description Selection/input Factory settings
Corrected
volume flow
calculation
Select the reference
density for calculating the
corrected volume flow.
Fixed reference
density
Calculated
reference density
Reference
density according
to API 53
External
reference density
Calculated
reference density
External
reference
density
Shows external reference
density.
Floating-point
number with sign
Country-
dependent:
0 kg/Nl (0 lb/scf)
Fixed reference
density
The following option is
selected in the
Corrected volume flow
calculation parameter:
Fixed reference density
Enter the fixed value for
the reference density.
Positive floating-
point number with
leading sign
Country-
dependent:
0.001 kg/Nl
(0.062 lb/scf)
Reference
temperature
The following option is
selected in the
Corrected volume flow
calculation parameter:
Calculated reference
density
Enter the reference
temperature for
calculating the reference
density.
Floating-point
number with sign
Country-
dependent:
20 °C (68 ° F)
Linear
expansion
coefficient
The following option is
selected in the
Corrected volume flow
calculation parameter:
Calculated reference
density
Enter the linear, medium-
specific expansion
coefficient for calculating
the reference density.
0 to 1 0.0
Square
expansion
coefficient
For media with a non-
linear expansion pattern,
use this function to enter
a quadratic, medium-
specific expansion
coefficient for calculating
the reference density.
0 to 1 0.0
10.4.3 Carrying out a sensor adjustment
The Sensor adjustment submenu contains parameters that pertain to the functionality of
the sensor.
Navigation path
"Setup" menu → Advanced setup → Sensor adjustment
Structure of the submenu
Sensor adjustment
Installation direction
Zero point adjustment
Zero point adjustment control

Table of Contents