Technical data Proline Promass E 100 Modbus RS485
92 Endress+Hauser
Shock resistance Shock, half-sine according to IEC 60068-2-27
6 ms 30 g
Shock resistance Shock due to rough handling following IEC 60068-2-31
Interior cleaning SIP cleaning
CIP cleaning
Electromagnetic
compatibility (EMC)
As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21)
Complies with emission limits for industry as per EN 55011 (Class A)
Details are provided in the Declaration of Conformity.
16.9 Process
Medium temperature range –40 to +150 °C (–40 to +302 °F)
Dependency of ambient temperature on medium temperature
T
a
T
m
B
A
A0031121
 21 Exemplary representation, values in the table below.
T
a
Ambient temperature range
T
m
Medium temperature
A Maximum permitted medium temperature T
m
at T
a max
= 60 °C (140 °F); higher medium temperatures T
m
require a reduced ambient temperature T
a
B Maximum permitted ambient temperature T
a
for the maximum specified medium temperature T
m
of the
sensor
Values for devices used in the hazardous area:
Separate Ex documentation (XA) for the device .
Density 0 to 5 000 kg/m
3
(0 to 312 lb/cf)
Pressure-temperature
ratings
An overview of the pressure-temperature ratings for the process connections is
provided in the "Technical Information" document