Proline Promass F 500 Modbus RS485 Operation
Endress+Hauser 147
Parameter overview with brief description
Parameter Prerequisite Description User interface / User
entry
Factory setting
Output frequency In the Operating mode
parameter, the Frequency
option is selected.
Displays the value currently
measured for the frequency
output.
0.0 to 12 500.0 Hz –
Value per pulse In the Operating mode
parameter, the Pulse option is
selected and one of the
following options is selected in
the Assign pulse output
parameter (→ 106):
• Mass flow
• Volume flow
• Corrected volume flow
• Target mass flow
*
• Carrier mass flow
*
Enter measured value at which
a pulse is output.
Signed floating-point
number
Depends on country
and nominal
diameter
Switch status The Switch option is selected
in the Operating mode
parameter.
Displays the current switch
output status.
• Open
• Closed
–
* Visibility depends on order options or device settings
Output values for relay output
The Relay output 1 to n submenu contains all the parameters needed to display the
current measured values for every relay output.
Navigation
"Diagnostics" menu → Measured values → Output values → Relay output 1 to n
‣
Relay output 1 to n
Switch status
→ 147
Switch cycles
→ 147
Max. switch cycles number
→ 147
Parameter overview with brief description
Parameter Description User interface
Switch status Shows the current relay switch status. • Open
• Closed
Switch cycles Shows number of all performed switch cycles. Positive integer
Max. switch cycles number Shows the maximal number of guaranteed switch cycles. Positive integer
Output values for double pulse output
The Double pulse output submenu contains all the parameters needed to display the
current measured values for every double pulse output.