Promag 53 PROFIBUS-DP/-PA 3 Installation
Endress+Hauser 13
3.2 Installation conditions
3.2.1 Dimensions
Dimensions and the fitting lengths of the transmitter and sensor are on Page 145 ff.
3.2.2 Mounting location
Correct measuring is possible only if the pipe is full. Avoid the following locations:
Highest point of a pipeline. Risk of air accumulating.
Directly upstream of a free pipe outlet in a vertical pipe.
Fig. 5: Mounting location
Installation of pumps
Do not install the sensor on the intake side of a pump. This precaution is to avoid low
pressure and the consequent risk of damage to the lining of the measuring tube. Infor-
mation on the lining's resistance to partial vacuum can be found on
Page 142.
It might be necessary to install pulse dampers in systems incorporating reciprocating,
diaphragm or peristaltic pumps. Information on the measuring system's resistance to
vibration and shock can be found on
Page 133.
Fig. 6: Installation of pumps
F06-5xxxxxxx-11-00-00-xx-000
F06-5xxxxxxx-11-00-00-xx-001