Promag 53 PROFIBUS-DP/-PA 5 Operation
Endress+Hauser 63
5 Operation
5.1 Operation at a glance
You have a number of options for configuring and commissioning the device:
1. Local display (Option)
Page 64
The local display enables you to read all of the important parameters directly at the
measuring point, configure device-specific parameters in the field and commission the
instrument.
2. Configuration program
Page 75
The configuration of profile and device-specific parameters is primarily done via the
PROFIBUS-DP/-PA interface. You can obtain special configuration and operating pro-
grams from the various manufacturers for these purposes.
3. Jumpers and miniature switches for hardware settings
Page 83
You can make the following hardware settings for the PROFIBUS-DP/-PA using jumpers
or miniature switches on the I/O board:
Set the device bus address
Switch the hardware write protection on or off
Fig. 41: Options for operating the Promag 53 PROFIBUS-DP/-PA
1 Configuration / operation programs for operating the device via the PROFIBUS-DP/-PA
2 Jumpers or miniature switches for hardware settings (write protection, device address)
3 Local display for the operation of the device in the field (option)
F06-xxxPBxxx-19-xx-xx-xx-000
1
2
3
E
-
+