Configuring Switches in a Stack
3-14 Hardware Installation
2. (Optional)Ifdesired,changethemanagementswitchusingthesetswitch
movemanagementcommandasdescribedintheSecureStackC2ConfigurationGuide.
3. Oncethedesiredmasterswitchhasbeenselected,resetthesystemusingthereset
commandasdescribedintheSecureStackC2ConfigurationGuide.
Adding a New Switch to an Existing Stack
Usethefollowingproceduretoinstallanewswitchtoanexistingstackconfiguration.
Thisprocedureassumesthatthenewswitchbeingaddedhasacleanconfigurationfrom
manufacturingandisrunningthesamefirmwareimageversionasotherswitchesinthe
stack.
1. Ensurethatpowerisoffonthenew
switchbeinginstalled.
2. Useoneofthefollowingmethodstocompletethestackcableconnections:
–Iftherunningstackusesadaisychaintopology,makethestackcableconnections
fromthebottomofthestacktothenewswitch(thatis,STACKDOWNportfrom
thebottomswitchoftherunningstack
totheSTACKUPportonthenewswitch).
–Iftherunningstackusesaringstacktopology,breaktheringandmakethestack
cableconnectionstothenewswitchtoclosethering.
3. Applypowertothenewswitch.
Important Considerations About Using Clear Config in a Stack
When using the clear config command (as described in the SecureStack C2 Configuration Guide)
to clear configuration parameters in a stack, it is important to remember the following:
Use clear config to clear config parameters without clearing stack switch IDs. This command
WILL NOT clear stack parameters and avoids the process of re-numbering the stack.
Use clear config all when it is necessary to clear all config parameters, including stack switch
IDs and switch priority values.