Using the Reset Button
4-8 Troubleshooting
Using the Reset Button
Ifyouforgettheswitchloginpassword,use theResetbuttonasdescribedinthefollowing
procedure.
Figure 4-3 Reset Button
Port(s) goes into
standby for no
apparent reason.
Loop condition detected. Verify that Spanning Tree is enabled. Refer to the
SecureStack C2 Configuration Guide for the instructions to
set the type of STA.
Review the network design and delete unnecessary loops.
If the problem continues, contact Enterasys Networks for
technical support.
User parameters
(IP address, device
and module name,
etc.) were lost
when the switch
power was cycled.
Clear NVRAM was set using
CLI commands.
Reenter the lost parameters as necessary. Refer to the
SecureStack C2 Configuration Guide for the instructions to
configure the switch using CLI commands.
If the problem continues, contact Enterasys Networks for
technical support.