Connecting to Console Port for Local Management
SecureStack C2 Installation Guide 3-17
•TheConsoleportoneachMemberswitchisdeactivated.OnlytheConsoleportonthe
Managerswitchisactiveforout‐ofband configurationtosettheIP address,password
andotherconfigurationsettings.
OnceyouknowwhichswitchistheManager,proceedto“ConnectingtoConsolePortfor
LocalManagement
”onpage 3‐17.
Connecting to Console Port for Local Management
ThissectiondescribeshowtoinstallanRS232DTEinterfacecabletoaPC,aVTseries
terminal,oramodemtoanEnterasysC2G124‐48PorC2H124‐48Pforout‐of‐band
sessionsusingCLIcommands.
What Is Needed
Thefollowingisalistofuser‐suppliedDTEinterfacecablesthatmaybeneededtoconnect
theDB9male Consoleportconnectorontheswitch.ThecablesareterminatedbyaDB9
femaleconnectoratoneend,andbyoneofthreetypeconnectorsattheotherend,
dependingon
thetypeconnectionneededfortheremotedevice.Thecablesthatmaybe
neededareasfollows:
•DB9female‐to‐DB9female
•DB9female‐to‐DB25female
•DB9female‐to‐DB25male
UsingaDTEmodemDB9female‐to‐DB9femalecable,youcanconnectproducts
equippedwithaDB9DTEmale
consoleporttoanIBMorcompatiblePCrunningaVT
seriesemulationsoftwarepackage.
UsingaDTEmodemDB9female‐to‐DB25femalecable,youcanconnectproducts
equippedwithaDB9DTEmaleconsoleporttoaVTseriesterminalorVTtypeterminals
runningemulationprogramsforthe
VTseries.
UsingaDTEmodemDB9female‐to‐DB25malecable,youcanconnectproductsequipped
withaDB9DTEmaleconsoleporttoaHayescompatiblemodemthatsupports
9600 baud.
ThecableusedmustconnecttheConsoleportReceivedData,Pin2totheTransmitted
Datapinatthe
otherendofthecable.TheconnectionfromtheConsoleportTransmitted
Data,Pin3(mustbeconnected)totheReceivedDatapincableconnectionatthe otherend
ofthecable.TheDB9ConsoleportpinassignmentsareshowninFigure 3‐9.
Note: When switches are connected in a stack configuration and all high-speed stacking
cables are connected before powering up the switches, one switch in the stack will be
automatically designated as the Manager of the stack and its Console port will remain
active. All other switches will become Member switches and their Console ports will be
deactivated.