EasyManua.ls Logo

Enterasys SecureStack C2 C2G124-48P - Poe Power; Stack Initialization Overview

Enterasys SecureStack C2 C2G124-48P
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connecting AC and PoE Power
3-16 Hardware Installation
3. ObservethepowerCPULED(notshown)locatedonthefrontpanel.Duringthe
initialization,theCPULEDwillstartbyilluminatingsolidamber,thenstartblinking
green,thenblinkingamber,thenblinkinggreenagainuntiltheendofthe
initialization,andthenturnssolidgreen.
Iftheswitchisa
standaloneunit,itwilltakeapproximately30 secondsfortheswitch
tostartup.IftheswitchisastackManager,itcantakeupto3minutesormoretostart
up,dependingonthenumberofMemberswitchesinthestack.
PoE Power
IfyouareinstallinganoptionalSecureStackC2PoEredundantpowersupply(C2RPS
POE),refertotheinstallationinstructionssuppliedwiththeC2RPSPOE.Theswitchis
connectedtoaC2RPSPOEusingaC2RPSPOECable.
Ifyouareinstallingtheswitchasastandalonedevice,proceedtoConnectingto
Console
PortforLocalManagementonpage 317.Ifyouareinstallingswitchesinastack
configuration,proceedtoStackInitializationOverviewonpage 316.
Stack Initialization Overview
Whenyouinstallandconnectallthehighspeedstackingcablestotheswitchesinthe
stackbeforeapplyingpowertotheswitches,thefollowingoccurs:
•Theswitchthatwillmanage(Manager)thestackisautomaticallyestablishedwithall
otherswitchesestablishedasMemberswitchesinthestack.Whentheswitches
completetheirinitializations,oneoftheswitchesinthestackwillilluminateits
ManagerLED,indicatingthatitisthestackManager.TheManagerLEDoneach
Memberswitchwillbeoff.
•ThehierarchyoftheswitchesthatwillfunctionasbackupManagerisalso determined
incasethecurrentManager
malfunctions,ispowereddown,orisdisconnectedfrom
thestack.
Note: If the CPU LED illuminates solid red, there was a critical failure. For more
information about the LED indications and troubleshooting, refer to Chapter 4. If you need
additional help, contact Enterasys Networks. Refer to “Getting Helpon page 1-7 for
details.
Caution: The C2G124-48P and C2H124-48P are PoE-compliant devices. Do not connect
a SecureStack C2 Redundant Power System (C2RPS-SYS) to the power connector.
Otherwise damage to the device may result.
Precaución: Los dispositivos C2G124-48P y C2H124-48P cumplen con el estándar PoE
(power over ethernet). No conecte una fuente de poder redundante SecureStack C2
(C2RPS-SYS) al cable de corriente. De lo contrario, el dispositivo puede dañarse.

Table of Contents

Related product manuals