Connecting AC and PoE Power
3-16 Hardware Installation
3. ObservethepowerCPULED(notshown)locatedonthefrontpanel.Duringthe
initialization,theCPULEDwillstartbyilluminatingsolidamber,thenstartblinking
green,thenblinkingamber,thenblinkinggreenagainuntiltheendofthe
initialization,andthenturnssolidgreen.
Iftheswitchisa
standaloneunit,itwilltakeapproximately30 secondsfortheswitch
tostartup.IftheswitchisastackManager,itcantakeupto3minutesormoretostart
up,dependingonthenumberofMemberswitchesinthestack.
PoE Power
IfyouareinstallinganoptionalSecureStackC2PoEredundantpowersupply(C2RPS‐
POE),refertotheinstallationinstructionssuppliedwiththeC2RPS‐POE.Theswitchis
connectedtoaC2RPS‐POEusingaC2RPS‐POECable.
Ifyouareinstallingtheswitchasastandalonedevice,proceedto“Connectingto
Console
PortforLocalManagement”onpage 3‐17.Ifyouareinstallingswitchesinastack
configuration,proceedto“StackInitializationOverview”onpage 3‐16.
Stack Initialization Overview
Whenyouinstallandconnectallthehigh‐speedstackingcablestotheswitchesinthe
stackbeforeapplyingpowertotheswitches,thefollowingoccurs:
•Theswitchthatwillmanage(Manager)thestackisautomaticallyestablishedwithall
otherswitchesestablishedasMemberswitchesinthestack.Whentheswitches
completetheirinitializations,oneoftheswitchesinthestackwillilluminateits
ManagerLED,indicatingthatitisthestackManager.TheManagerLEDoneach
Memberswitchwillbeoff.
•ThehierarchyoftheswitchesthatwillfunctionasbackupManagerisalso determined
incasethecurrentManager
malfunctions,ispowereddown,orisdisconnectedfrom
thestack.
Note: If the CPU LED illuminates solid red, there was a critical failure. For more
information about the LED indications and troubleshooting, refer to Chapter 4. If you need
additional help, contact Enterasys Networks. Refer to “Getting Help” on page 1-7 for
details.
Caution: The C2G124-48P and C2H124-48P are PoE-compliant devices. Do not connect
a SecureStack C2 Redundant Power System (C2RPS-SYS) to the power connector.
Otherwise damage to the device may result.
Precaución: Los dispositivos C2G124-48P y C2H124-48P cumplen con el estándar PoE
(power over ethernet). No conecte una fuente de poder redundante SecureStack C2