Using LANVIEW
4-6 Troubleshooting
Link/
Activity
(RJ45
PoE ports
1–48)
Off 1. No link.
2. No activity or port in standby.
3. The port is deactivated because the
Mini-GBIC port with the same port number
is linked.
None.
None.
None.
Green Solid. Port is linked, but the interface is not
receiving any traffic. PoE power is okay.
None.
Blinking. Port is linked and traffic is being
received or transmitted by the interface. PoE
power is okay.
None.
Amber Solid. Port is linked, but traffic is not being
received or transmitted by the interface. PoE
power has failed.
PoE power may have been deactivated because
of excessive power requirement or deactivated
by configuration.
Power Supply failed.
1. Check the attached powered device
to see if it is defective.
2. Internal power supply failed, contact
Enterasys Networks for technical
support.
Blinking. Port is linked and traffic is being
received or transmitted by the interface. PoE
power has failed.
PoE power may have been deactivated because
of excessive power requirement or deactivated
by configuration.
Power supply failed.
1. Check the attached powered device
to see if it is defective.
2. Internal power supply failed, contact
Enterasys Networks for technical
support.
Link/
Activity
(MGBIC
ports 45–
48)
Off 1. No link.
2. No activity or port in standby.
3. The port is deactivated because the RJ45
port with the same port number is linked.
None.
None.
None.
Green Solid. Port is linked, but the interface is not
receiving any traffic.
None.
Blinking. Port is linked and traffic is being
received or transmitted by the interface.
None.
Table 4-1 LANVIEW LED Diagnostic Indications (continued)
LED Color State Recommended Action