5050 CONTROL UNIT
Technical Manual & Cabling Instructions
19.10.2012
Epec Oy reserves all rights for improvements without prior notice
Epec Oy Postiosoite/Postal address Puhelin/Phone Fax Internet
Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 +358-(0)20-7608 110 www.epec.fi
FIN-60320 Seinäjoki FIN-60101 Seinäjoki, Finland
X1.33 PWM/DO/DI
Power 1 4A
X1.34 PWM/DO/DI
Power 1 4A
X1.35 PWM/DO/DI
Power 1 4A
X2.13 PWM/DO/DI/CM
Power 1 2A
X2.14 PWM/DO/DI/CM
Power 1 2A
X2.26 DO_GND
Power 1 3A
X2.27 DO_GND
Power 1 3A
X2.34 DO_GND
Power 1 3A
X2.35 DO_GND
Power 1 3A
X2.28 PWM/DO/DI/CM
Power 2 2A
X2.29 PWM/DO/DI/CM
Power 2 2A
X2.30 PWM/DO/DI/CM
Power 2 2A
X2.31 PWM/DO/DI/CM
Power 2 2A
X2.32 PWM/DO/DI/CM
Power 2 2A
X2.33 PWM/DO/DI/CM
Power 2 2A
X3.26 PWM/DO/DI/CM
Power 2 2A
X3.27 PWM/DO/DI/CM
Power 2 2A
X3.28 PWM/DO/DI/CM
Power 2 2A
X3.29 PWM/DO/DI/CM
Power 2 2A
X3.30 PWM/DO/DI/CM
Power 2 2A
X3.31 PWM/DO/DI/CM
Power 2 2A
X3.32 PWM/DO/DI/CM
Power 2 2A
X3.33 PWM/DO/DI/CM
Power 2 2A
X3.34 PWM/DO/DI/CM
Power 2 2A
X3.35 PWM/DO/DI/CM
Power 2 2A
Connector pin
number
Current / Pin Note
The maximum sum of GND pin currents cannot exceed
28 A.
If the Logic power is >43 V, there is a risk that the control unit shuts down.
If Power1 or Power2 is > 43 V, the outputs in the group must be disabled.